XS500
The XS500 is designed for environments where strength and durability are non-negotiable, yet it doesn’t shy away from delivering a touch of elegance. Capable of handling the heaviest loads with grace, this model is a true workhorse, seamlessly blending industrial might with refined design. Whether in a factory, industrial facility, or a large shopping mall, the XS500 stands out as a symbol of robust engineering and sophisticated aesthetics, ensuring reliable performance in even the most demanding settings.
- Elevator

Technical summary
- Load capacity
- 5,000 kg3,000 · 3,500 · 4,000 · 5,000 kg
- Speed
- 1.6 m/s1.0 · 1.6 m/s
- Max. travel height
- 60 m
- Max. stops
- 20
- Machine room
- MR / MRL
The complete dimension tables — car, door, shaft, headroom and pit — are in the fact sheet.
Standard and optional equipment
85 items available for this model, grouped by system. Standard items are included; optional items are quoted on request.
Standards15
- EN81-20 / 50Standard
- EN81-28Standard
- EN81-58Standard
- EN81-70Optional
- EN81-71Optional
- Cat.0Optional
- Cat.1Optional
- Cat.2Optional
- EN81-72Optional
- EN81-73Standard
- EN81-77Optional
- Cat.1Optional
- Cat.2Optional
- Cat.3Optional
- EN12015 - EN12016Optional
Suspension ratio1
- Suspension 4:1Standard
Traction machine4
- Machine Ziehl AbeggOptional
- Machine Alberto SassiOptional
- Machine WITTUROptional
- Machine TORINStandard
Inverter3
- Inverter ZetaDynOptional
- Inverter ARKELStandard
- Inverter YASKAWAOptional
Controller2
- ARKEL ARCODE ControllerStandard
- WEBER THOR E2 ControllerOptional
Safety gear3
- Safety Gear WitturOptional
- Safety Gear KobianchiOptional
- Safety Gear DynatechStandard
Cabin wall structure4
- Cabin wall panels (single leaf) [only for powder coating]Optional
- Cabin wall panels (twin leaf)Standard
- Cabin wall panels (twin leaf - MDF supported)Optional
- Cabin wall panels (twin leaf - Isolution pad)Optional
Cabin wall finishes10
- Powder Coated RAL 9006 White Aluminium WallsStandard
- Powder Coated RAL 9016 Trafic White WallsStandard
- Powder Coated RAL 7032 Pebble Grey WallsStandard
- Stainless Steel Satin AISI304Optional
- Stainless Steel Linen AISI304Optional
- Stainless Steel Diamond AISI304Optional
- Stainless Steel Leather AISI304Optional
- Stainless Steel Mirror AISI304Optional
- Coloured Stainless Steel [Bronze, Gold, Champaign, Black]Optional
- Stainless Steel - MESH CombinationOptional
Cabin equipment9
- Car ceilingStandard
- False Ceiling (AISI 304 or other cladding) LED LightingOptional
- Car ventilation - indirect - invisibleOptional
- Car ventilation with on/off buttonOptional
- Handrail on rear wallStandard
- Handrail on rear + side wallsOptional
- Handrail on all wallsOptional
- Bumper (MDF)Standard
- Bumper (Stainless Steel)Optional
Door supplier / model4
- Fermator MEGAOptional
- Fermator PremiumOptional
- Wittur HydraOptional
- Wittur PegasusOptional
Door options11
- EN81-58 E120 Fire RatedStandard
- EN81-58 EI60 Fire RatedOptional
- EN81-71 AntivandalOptional
- Heavy Duty Goods Elevator DoorOptional
- IP54 ProtectionOptional
- IPX3 ProtectionOptional
- 4 Panel Central OpeningOptional
- 6 Panel Central OpeningOptional
- Reinforced Aluminium SillStandard
- Steel SillOptional
- Reinforced Steel SillOptional
Door closing1
- Spring / CounterweightOptional
Controller functions18
- Regenerative InverterOptional
- Halogen Free wiringOptional
- Group Control Up to 32 LiftStandard
- Control Box (Surface Mounted)Standard
- Control Box (In wall)Standard
- Slim Control Box ( Splited parts will be in shaft)Optional
- Control Box in Top LandingStandard
- Control Box removed from shaft up to 3mOptional
- Control Box in any landingOptional
- Automatic Rescue Device to the nearest landingStandard
- Automatic Rescue Device to any landingOptional
- Generator connectionOptional
- Service Hour MeterOptional
- Trip MeterOptional
- 5 way Intercom with GSM ModuleOptional
- Advance Door OpeningOptional
- RelevellingOptional
- Door nudging with audience signalOptional
Application areas
- Production
- Shopping mall
Standards and options
- EN81-20 / 50Safety rules for construction and installationStandard
- EN81-28Remote alarmStandard
- EN81-58Landing door fire resistanceStandard
- EN81-70Accessibility, including persons with disabilityOption
- EN81-71Vandal resistant liftsOption
- EN81-72Firefighters liftsOption
- EN81-73Behaviour in the event of fireStandard
- EN81-77Lifts subject to seismic conditionsOption
- EN12015 - EN12016Electromagnetic compatibilityOption
Conformity and warranty
Bronze Lift designs and supplies lift systems and safety components in accordance with EN 81-20 and EN 81-50, and issues the EU declaration of conformity for the systems it supplies.
Bronze Lift does not carry out installation. Under Directive 2014/33/EU the final conformity assessment and the CE marking of the installed lift are the responsibility of the installer, who appoints the notified body.
All supplied products carry a standard 24-month manufacturer's warranty from the date of delivery.
Quality certificates for the facilities where the products are manufactured can be provided on request.